The Use of Sucking Pump
Preparation
M5Stack series: Make sure robot is connected with PC (Go to 5.1 myBlockly for more information).
Other series: Make sure the robot is in normal status.
This section takes myPalletizer 260 M5Stack as an example to explain the use of suction pump. Go to 2.8 Accessories for more information about sucking pump.
Purpose for this section
This section introduces instructions for using sucking pump.
Introduction to API
Notice: M5Stack version is unable to use the blocks belonging to Raspberry Pi version. Otherwise, the system may report an error.
Set Basic pin () output ()
(for M5Stack version)Applicable to myCobot 280 series, mechArm 270 series, and myPalletizer 260 series
Parameter:
pin ()
: the numerical part of the numbers marked at the bottom of the equipmentoutput ()
:0
means setting to the running state, and1
means setting to the stop state
Function: set the working state of the preset bottom pin
get_basic_input(pin_no)
(for M5Stack version)
- Applicable to myCobot 280 series, mechArm 270 series, and myPalletizer 260 series
- Parameter:
pin()
: the numerical part of the numbers marked at the bottom of the equipment
- Function: get the working state of the bottom pin number
set mode ()
(for Raspberry Pi version )
- Applicable to myCobot 280 series, mechArm 270 series, and myPalletizer 260 series
- Parameter:
mode()
: "BCM" or "BOARD"
- Function: set Raspberry Pi GPIO Pin Mode
set pin() mode()
(for Raspberry Pi version )
- Applicable to myCobot 280 series, mechArm 270 series, and myPalletizer 260 series
- Parameter:
pin ()
: the numerical part of the numbers marked at the bottom of the equipmentmode ()
:in
means signal import, andOUT
means signal output
- Function: set signal of the preset bottom pin
set pin() output()
(for Raspberry Pi version )
- Applicable to myCobot 280 series, mechArm 270 series, and myPalletizer 260 series
- Parameter:
pin()
: the numerical part of the numbers marked at the bottom of the equipmentoutput()
:HIGH
means high level of sucking pump working state, andLOW
means low level of sucking pump working state
- Function: set the working state of bottom pin to high level or low level
Simple Demo
Program for display:
Motion:
Sucking pump vibrates and work to suck objects,
after 2 seconds, sucking pump put objects down,
after 2 seconds, it vibrates again. The whole process loops 5 times.